The classification of hazardous areas of global main explosion-proof system and corresponding protection methods

Hazardous Locations Marking Examples

Markings for Global IECEx System/for China

 

Area Classification-Division Versus Zone

Type of Area NEC and CEC(North America) IEC,China and CENELEC
Continuous Hazard Division 1 or Zone 0/Zone 20 Zone 0/Zone 20
Intermittent Hazard Division 1 or Zone 1/Zone 21 Zone 1/Zone 21
Hazard Under Abnormal Conditions Division 2 or Zone 2/Zone 22 Zone 2/Zone 22

ATEX Equipment Category and IEC/IECEx Equipment Protection Level

Equipment
Group
ATEX Equoipment
Category
Environment IEC/EN Explosion
Protection Level
Level of
Protection
Presence or Duration
of Explosive Atmosphere
Correlation with
Hazardous Areas
I M1 Mine
(Methane,
Coal dust)
Ma Very High Presence  
M2 Mb High Risk of Presence  
II 1 G-Gas Ga(for gas) Very High Continuous presence Zone 0(Gas/Vapor)
2 Ga(for gas) High Likely to occur Zone 1(Gas/Vapor)
3 Ga(for gas) Lower Unlikely to occur Zone 2(Gas/Vapor)
III 1 D-Dust Da(for dust) Very High Continuous presence Zone 20(Dust)
2 Da(for dust) High Likely to occur Zone 21(Dust)
3 Da(for dust) Lower Unlikely to occur Zone 22(Dust)

Explosive/Flammable/Combustible Atmosphere/Environment Grouping 

Division System Zone System
Typical Gas/Dust Fibers/Flyings  Canada(CEC) Canada(CEC)  Typical Gas/Dust Fibers/Flyings
Acetylene Class I,Group A Group IIC Acetylene
Hydrogen Class I,Group B Hydrogen
Ethylene Class I,Group C Group IIB Ethylene
Propane Class I,Group D Group IIA Propane
Methane(Mines) Gaseous Mines Group I Methane(Mines)
Metal Dusts Class II,Group E Group IIIC Conductive Dusts
Coal Dusts Class II,Group F Group IIIB Non-Conductive Dusts
Grain Dusts Class II,Group G
Fibers/Flyings Class II Group IIIA Combustible Flyings

Temperature Code & Temperature Class

Maximum Surface
Temperature(℃)

US(NEC)
Canada(CEC)

IEC,China,European
Canada(CEC)

450

T1

T1

300

T2

T2

280

T2A

-

260

T2B

-

230

T2C

-

215

T2D

-

200

T3

T3

180

T3A

-

165

T3B

-

160

T3C

-

135

T4

T4

120

T4A

-

100

T5

T5

85

T6

T6

Ingress Protection(IP)Codes

First Numeral-Protection Against Solid Bodies
0 No Protection
1 Objects greater than 50mm
2 Objects greater than 12.5mm
3 Objects greater than 2.5mm
4 Objects greater than 1.0mm
5 Dust-Protected
6 Dust-Tight
 

Temperature Code & Temperature Class

Maximum Surface
Temperature(℃)

US(NEC)
Canada(CEC)

IEC,China,European
Canada(CEC)

450

T1

T1

300

T2

T2

280

T2A

-

260

T2B

-

230

T2C

-

215

T2D

-

200

T3

T3

180

T3A

-

165

T3B

-

160

T3C

-

135

T4

T4

120

T4A

-

100

T5

T5

85

T6

T6

Protection Methods for Potentially Explosive Gas/Vapor Atmospheres

Second Numeral-protection Against Water
0 No Protection
1 Vertical Dripping
2 Angled Dripping(15°titled)
3 Spraying
4 Splashing
5 Jetting
6 Powerful Jetting
7 Temporary Immersion
8 Continuous Immersion

Protection Methods for Potentially Explosive Gas/Vapor Atmospheres(continue the above table)

TYPE OF
PROTECTION

CODE

MARKET

APPLICATION

STANDARD

PROTECTION
PRINCIPLE

 General
 Requirements
 for Hazardous
 Locations
 

 Ex
 Ex
 AEx
 Ex
 Ex
 

 IEC
 China
 US
 US
 CA
 EU

 EPL Ga,Gb,&Gc
 EPL Ga,Gb,&Gc
 Class I,Division I &2
 Class I,Zone I &2
 Class I,Zone I &2
 Category 1G,2G&3G

 IEC 60079-0
 GB 3836.1
 FM 3600
 ISA 60079-0
 CSA C22.2 No.60079-0
 EN 60079-0

 

 Incareased
 Safety

 Ex e (or Ex eb)
 Ex e (or Ex eb)
 AEx e (or AEx eb)
 Ex e
 Ex e (or Ex eb)

 IEC
 China
 US
 CA
EU

 EPL Gb
 EPL Gb
 Class I,Zone 1
 Class I,Zone 1
 Category 2G

 IEC 60079-7
 GB 3836.3
 ISA 60079-7
 CSA C22.2 No.60079-07
 EN60079-7

 

 Non-Incendive

 (NI)
 (NI)
 

 US
 CA
 

 Class I,Division 2
 Class I,Division 2
 

 ISA 12.12.01/FM 3611
 CSA C22.2 No.213
 

 No arcs
 sparks or
 hot surfaces

 Non-Sparking

 Ex nA (or Ex nAc)
 Ex nA (or Ex nAc)
 AEx nA (or AEx nAc)
 Ex nA
 Ex nA (or Ex nAc)

 IEC
 China
 US
 CA
 EU

 EPL Gc
 EPL Gc
 Class I,Zone 2
 Class I,Zone 2
 Category 3G

 IEC 60079-15
 GB 3836.8
 ISA 60079-15
 CSA C22.2 No.60079-15
 EN 60079-15

 

 Non-Sparking

 Ex nA (or Ex nAc)
 Ex nA (or Ex nAc)
 AEx nA (or AEx nAc)
 Ex nA
 Ex nA (or Ex nAc)

 IEC
 China
 US
 CA
 EU

 EPL Gc
 EPL Gc
 Class I,Zone 2
 Class I,Zone 2
 Category 3G

 IEC 60079-15
 GB 3836.8
 ISA 60079-15
 CSA C22.2 No.60079-15
 EN 60079-15

 

 Explosion-proof

 (XP)
 (XP)

 US
 CA

 Class I,Division 1
 Class I,Division 1

 UL 1203/FM 3615
 CSA C22.2 No.30

 

 Flame-proof

 Ex d (or Ex db)
 Ex d (or Ex db)
 AEx d (or AEx db)
 Ex d
 Ex d (or Ex db)

 IEC
 China
 US
 CA
 EU

 EPL Gb
 EPL Gb
 Class I,Zone 1
 Class I,Zone 1
 Category 2G

 IEC 60079-1
 GB 3836.2
 ISA 60079-1
 CSA C22.2 No.60079-1
 EN 60079-1

 Control the
 explosion and
 extinguish
 the flame

 Enclosed Break

 Ex nC (or Ex nCc)
 Ex nC (or Ex nCc) 
 AEx nC (or AEx nCc)
 Ex nC
 Ex nC (or Ex nCc)

 IEC
 China
 US
 CA
 EU

 EPL Gc
 EPL Gc
 Class I,Zone 2
 Class I,Zone 2
 Category 3G

 IEC 60079-15
 GB 3836.8
 ISA 60079-15
 CSA C22.2 No.60079-15
 EN 60079-15

 

Intrinsic Safety

Ex ia,ib,ic

 Ex ia,ib,ic

 (IS)

 (IS)

 AEx ia

 AEx ib

 Ex ia

 Ex ib

 Ex ia,ib,ic

 AEx ic

 Ex ic

IEC

 China

 US

 CA

 US

 US

 CA

 CA

 EU

 US

 CA

 EPL Ga,Gb,Gc

 EPL Ga,Gb,Gc

 Class I,Division 1

 Class I,Division 1

 Class I,Zone 0

 Class I,Zone 1

 Class I,Zone 0

 Class I,Zone 1

 Category 1G,2G,2G

 Class I,Zone 2

 Class I,Zone 2

IEC 60079-11

 GB 3836.4

 UL 913/FM 3610

 CSA C22.2 No.157

 ISA 60079-11/FM 3610

 ISA 60079-11/FM 3610

 CSA C22.2 No.60079-11

 CSA C22.2 No.60079-11

 EN 60079-11

 ISA 60079-11/FM 3610

 CSA C22.2 No 60079-11

Limit energy

 of sparks and

 surface

 temperature

Protection methods for combustible/ignitable dust atmospheres(including fiber and flyings)

TYPE OF

PROTECTION

CODE

MARKET

APPLICATION

STANDARD

PROTECTION

PRINCIPLE

Pressurization

 Type X,Y

 Type X,Y

 Type Z

 Type Z

 Ex px(or Ex pxb)

 Ex px(or Ex pxb)

 AEx px(or AEx pxb)

 Ex px

 Ex px (or Ex pxb)

 Ex py (or Ex pxb)

 Ex py (or Ex pxb)

 AEx py(or AEx pxb)

 Ex py

 Ex py (or Ex pyb)

 Ex pz (or Ex pzb)

 Ex pz (or Ex pzb)

 AEx pz (or AEx pzb)

 Ex pz (or Ex pzb)

 Ex pz (or Ex pzb)

US

CA

US

CA

IEC

China

US

CA

EU

IEC

China

US

CA

EU

IEC

China

US

CA

EU

 Class I,Division 1

 Class I,Division 1

 Class I,Division 2

 Class I,Division 2

 EPL Gb

 EPL Gb

 Class I,Zone 1

 Class I,Zone 1

 Category 2G

 EPL Gb

 EPL Gb

 Class I,Zone 1

 Class I,Zone 1

 Category 2G

 EPL Gc

 EPL Gc

 Class I,Zone 2

 Class I,Zone 2

 Category 3G

 FM 3620 (NFPA 496)

 NFPA 496

 FM 3620 (NFPA 496)

 NFPA 496

 IEC 60079-2

 GB 3836.5

 ISA 60079-2

 CSA C22.2 No.60079-2

 EN 60079-2

 IEC 60079-2

 GB 3836.5

 ISA 60079-2

 CSA C22.2 No.60079-2

 EN 60079-2

 IEC 60079-2

 GB 3836.5

 ISA 60079-2

 CAS C22.2 No.60079-2

 EN 60079-2

 

Restricted
Breathing

 Ex nR (or Ex nRc)

 Ex nR (or Ex nRc)

 AEx nR(or AEx nRc)

 Ex nR

 Ex nR (or Ex nRc)

IEC

China

US

CA

EU

 EPL Gc

 EPL Gc

 Class I,Zone 2

 Class I,Zone 2

 Category 3G

 IEC 60079-15

 GB 3836.8

 ISA 60079-15

 CSA C22.2 No.60079-15

 EN60079-15

 

Keep

flammable

gas out

 

 

Encapsulation

 Ex ma,mb,mc

 Ex ma,mb,mc

 Ex ma,mb,mc

 AEx ma

 Ex ma

 Aex mb

 Ex mb

 AEx mc

 Ex mc

IEC

China

EU

US

CA

US

CA

US

CA

 EPL Ga,Gb,Gc,

 EPL Ga,Gb,Gc,

 Category 1G,2G,3G

 Class I,Zone 0

 Class I,Zone 1

 Class I,Zone 1

 Class I,Zone 1

 Class I,Zone 2

 Class I,Zone 2

 IEC 60079-18

 GB 3836.9

 EN 60079-18

 ISA 60079-18

 CSA C22.2 No.60079-18

 ISA 60079-18

 CSA C22.2 No.60079-18

 ISA 60079-18

 CSA C22.2 No.60079-18

 

Oil lmmersion

 Ex o (or Ex ob)

 Ex o (or Ex ob)

 AEx o (or AEx b)

 Ex o

 Ex o (or Ex ob)

IEC

China

US

CA

EU

 EPL Gb

 EPL Gb

 Class I,Zone 1

 Class I,Zone 1

 Category 2G

 IEC 60079-6

 GB 3836.6

 ISA 60079-6

 CSA C22.2 No.60079-6

 EN60079-6

 

Powder-Filling

 Ex q (or Ex qb)

 Ex q (or Ex qb)

 AEx q (or AEx qb)

 Ex q

 Ex q (or Ex qb)

IEC

China

US

CA

EU

 EPL Gb

 EPL Gb

 Class I,Zone 1

 Class I,Zone 1

 Category 2G

 IEC 60079-5

 GB 3836.7

 ISA 60079-5

 CSA C22.2 No.60079-5